xgenus Arïes has been thought to satisfy the needs of the most exigent specialists. The device encloses the finest technology of de Götzen and its decennial know-how on user experience, all packed in a stunning design.
Let Arïes surprise you with its smart solutions: a compact 2D or 2D/3D imaging device without any compromise, xgenus Arïes can be seamlessly integrated in any clinical environment thanks to its incredible 0 footprint and clean design.
Enjoy the details: with xgenus Arïes the diagnostic process is made fast and reliable, the device is designed to provide you high quality images in just few clicks. The new eye catching design, the new outstanding resolution of 72.5 µm, the new impressive SMAR-T filter for Metal Artifacts automatic compensation make it even easier, pleasant and effective than never before.
Face to face positioning design of xgenus Arïes allows better communication with your patient during the pre-exam phase, its automatic positioning solutions ensure the highest comfort for you and your patient.
Integration, connectivity and scalability are the keywords of the new xgenus Arïes empowered by AIS 5, the imaging software developed around the customer and his daily workflow.
TECHNICAL DATA | ||||
xgenus Arïes | xgenus Arïes Ceph | xgenus Arïes 3D | xgenus Arïes 3D Ceph | |
---|---|---|---|---|
X-RAY SOURCES | ||||
Total Filtration | 2.5 mm Al eq. @ 70kVp | ≥ 2.5 mm Al eq. @ 86kVp | ≥ 2.5 mm Al eq. @ 86kVp | ≥ 2.5 mm Al eq. @ 86kVp |
Tube Voltage | 60 - 70 kV | 60 - 86 kV | 60 - 86 kV | 60 - 86 kV |
Anodic current | 2 - 7.1 mA | 2 - 12.5 mA | 2 - 12.5 mA | 2 - 12.5 mA |
Focal spot | 0.5 | 0.5 | 0.5 | 0.5 |
DETECTORS | ||||
Type | CCD | CMOS detectors with CsI scintillator | CMOS Flat Panel | CMOS detectors with CsI scintillator |
Pixel size | 96 µm (2x2 binning) | 99 µm minimum | 100 µm | 99 µm minimum |
Voxel size | n.a. | n.a. | 145-175 μm Standard 72.5-87.5 μm High resolution | 145-175 μm Standard 72.5-87.5 μm High resolution |
ACQUISITION | ||||
2D Programs | Panoramic (adult/child) - Lateral TMJ (open/closed mouth) - Maxillary Sinuses (PA) - Half panoramic (L/R) - Low Dose Panoramic Frontal Dentition - Bitewing (L/R(Bilateral) - Ortho Rad Panoramic | |||
3D Programs | Full dentition (85x90 mm - ØxH) - Single jaw (85x50 mm - ØxH) Mandibular teeth (50x50 mm ØxH)) - Maxillary teeth (50x50 mm ØxH) TMJ (85x90 mm ØxH) - Maxillary Sinuses (85x90 mm ØxH) Extended dentition (120x100 mm ØxH) - Extended airways (120x100 mm ØxH) | |||
Ceph Programs | Skull Latero-Lateral (HxL) (24x18 cm - 18x18 cm) (24x24 cm - 18x24 cm) (24x30 cm - 18x30 cm) Skull Antero-Posterior (HxL) (24x24 cm - 18x24cm) Carpus (HxL) (24x18 cm) | Skull Latero-Lateral (HxL) (24x18 cm - 18x18 cm) (24x24 cm - 18x24 cm) (24x30 cm - 18x30 cm) Skull Antero-Posterior (HxL) (24x24 cm - 18x24cm) Carpus (HxL) (24x18 cm) | ||
Exposure time | up to 14 s | from 4.3 s | from 5.7 s | from 4.3 s |
Gray levels | 4096 (12 bit) | 16384 (14 bit) | 65536 (16 bit) | 16384 (14 bit) |
MECHANICAL DATA | ||||
Footprint | 1107x1063 mm | 1208x1859 | 1107x1063 mm | 1208x1859 |
Height | 2190 mm (max) | 2230 mm (max) | 2190 mm (max) | 2230 mm (max) |
Weight | 62 kg | 118 kg | 67 kg | 125 kg |
WORKSTATION MINIMUN REQUIREMENTS | |||
PAN/CEPH WINDOWS (WORKSTATION) | CLIENT WINDOWS | CLIENT MAC OS | |
---|---|---|---|
Processor | Intel Core i5 | Intel i5 | Intel Core i5 |
Hard Disk | 1 TB 7200 rpm | 300 GB | 300 GB |
RAM | 8 GB | 4 GB or 8 GB (for big FOV DICOM stacks) | 4 GB or 8 GB (for big FOV DICOM stacks) |
Graphic Card | Open GL 2.1 compatible (suggested NVIDIA GT/GTX) | NVIDIA Geforce or NVIDIA Quadro with 1 GB dedicated RAM | NVIDIA Geforce or NVIDIA Quadro with 1 GB dedicated RAM |
Screen resolution | 1600 x 1024 | 1600 x 1024 | 1600 x 1024 |
Network Card | Intel CT 1000 pro | 100 Mb for PAN/CEPH 1GB for CBCT | 100 Mb for PAN/CEPH 1GB for CBCT |
Operating System | Windows 10 Pro 64 bits | Windows 10 Pro 64 bits | OS X Catalina (10.15) |